Cold aisle or hot aisle containment with the ZPAS Databox · modular aisle containment with glass roof. Choose containment, rows, cabinet type, roof, doors, colour and accessories — the diagram and bill of materials update live. All components in detail: the Databox.
✓ Your data centre containment in a few steps
Put together your cold aisle or hot aisle containment (ZPAS Databox) step by step. The bill of materials in the sidebar grows as you go — at the end, you send everything as a no-obligation enquiry and we get back to you with a specific quotation.
Cable tray above the cold aisle? Design it to EN 61537 at the same time — go to the cable tray configurator →
Help with your choice: Guide: choosing the right server rack
Something special? Do you need special sizes, a specific aisle width, additional cable trays, a special cooling solution or redundancy that the configurator does not cover? Simply describe it in the remarks field of your enquiry or write to us at info@zpasgroup.de. We regularly plan data centre containment entirely on a project-specific basis.
Cold aisle: the cold supply air is contained – common with raised-floor or in-row cooling. Hot aisle: the warm exhaust air is contained. Both increase cooling efficiency; if in doubt, choose cold aisle.
U = rack unit (1 U = 44.45 mm of usable 19″ rack height). 42/45/47 U correspond to a cabinet height of approx. 2000/2100/2200 mm.
Width of the contained cold/hot aisle between the rows of cabinets.
Without a roof, the aisle is open at the top – we plan the separation from the room ceiling (e.g. curtain or on-site ceiling) on a project-specific basis. Please add details in the remarks field.
Sliding door (glass) — space-saving, included in the containment scope of supply. Hinged door variants on request via the remarks field.
Rear end closure Door locking All doors are self-closing (door closer) – choose the locking here.With a sheet steel wall at the rear, the containment has only one door (front) – access control and locking are therefore calculated only once.
Your complete configuration and bill of materials are sent directly with your enquiry. We usually reply within one working day.
Prefer to talk directly?
Our team in Leipzig plans your data centre containment together with you.
Note: All calculations, recommendations and illustrations in this configurator are non-binding approximations based on simplified methods and do not replace professional design in the individual case — we will be happy to check your values free of charge. All information is provided without guarantee: no liability is accepted for accuracy and completeness, or for any design or purchasing decision based on it. Only the details in our written quotation or order confirmation are binding. Subject to technical changes and errors.