The SZE2 PC is ZPAS’s sealed computer cabinet for dusty and dirty environments: degree of protection IP 54 according to EN 60529, three separately lockable compartments for monitor, keyboard and PC, built on the modified frame of the SZE2 industrial electrical enclosure — with 19″ interior fittings and a payload of up to 600 kg.
🌡️ Calculate the cooling for the SZE2 PCIP 54 makes it suitable for cooling units — enter the power loss, get a recommendation · free of charge →A PC workstation that belongs on the shop floor
Where chips fly, dust settles or splashing water occurs, an unprotected computer has no place. The SZE2 PC encloses the complete PC workstation for controlling work processes in an IP 54 cabinet — and controls access at the same time: three compartments with different half cylinders and keys separate the monitor (top, behind a glass door), keyboard (middle, pull-out drawer behind a flap with quarter-turn lock) and computer (bottom, behind a solid sheet steel door). The operator can reach the keyboard — only those with the right key can reach the PC itself.
Version table: three sizes
Width always 600 mm, depth 600 or 800 mm. The PC section at the bottom stays constant at 18 U, the monitor section at the top grows with the frame height. Source: ZPAS IT catalogue.
| SZE2 PC 33 U | SZE2 PC 38 U | SZE2 PC 42 U | |
|---|---|---|---|
| Frame height H | 1,600 mm | 1,800 mm | 2,000 mm |
| Upper section (monitor) | 10 U | 15 U | 19 U |
| Lower section (PC) | 18 U | 18 U | 18 U |
| Width × depth | 600 × 600 mm or 600 × 800 mm | ||
Catalogue numbers of the standard version (width 600 mm, RAL 7035):
| Depth [mm] | 33 U (H 1600) | 38 U (H 1800) | 42 U (H 2000) |
|---|---|---|---|
| 600 | W-3004-00-06-011 | W-3004-00-04-011 | W-3004-00-02-011 |
| 800 | W-3004-00-05-011 | W-3004-00-03-011 | W-3004-00-01-011 |
Source: IT solutions catalogue, p. 51 (PDF) → · SZE2 PC datasheet (PDF, 1 page)
Need a different layout or dimensions? ZPAS manufactures special versions to customer requirements — just ask.
Cooling: thanks to IP 54, from filter fan to cooling unit
The PC and monitor heat up the closed cabinet — and unlike an open 19″ rack, the heat cannot simply escape. The good news: because the SZE2 PC meets IP 54, all cooling options are available, including the compressor cooling unit, which requires at least IP 54 on the cabinet and maintains the degree of protection in operation. With low power loss, a heat exchanger is often sufficient. The cooling capacity calculator works out how much cooling capacity is really needed from the power loss, cabinet dimensions and ambient temperature — and the guide to choosing a cooling unit explains which unit fits. The server rack cooling overview shows the cooling stages for 19″ server equipment.
Standard equipment from the factory
Related to the SZE2: bayable, expandable, also in stainless steel
Because the SZE2 PC is based on the SZE2 frame, it inherits its strengths: it can be bayed with further SZE2 PC cabinets or SZE2 electrical enclosures, and besides the 19″ accessories, the complete range of SZE2 electrical enclosure accessories fits as well. The payload: 600 kg mounted on a plinth, 500 kg mobile on type 300 castors. For food processing plants and corrosive environments, ZPAS manufactures the frame, doors, panels, roof and plinth in stainless steel on request — more on this in the materials guide. Also available as accessories: optional roof, castors, equipment shelves and socket strips.
The machine & plant building industry page shows where the SZE2 PC is typically used.
Frequently asked questions — SZE2 PC
What is the SZE2 PC intended for?
For PC use in dusty and dirty environments, e.g. for controlling work processes in production. Degree of protection IP 54 according to EN 60529; three compartments with separate half cylinders control who may access the monitor, keyboard or computer. The IP ratings guide explains what IP 54 means in practice.
Which sizes are available?
Three overall heights: 33, 38 and 42 U (frame 1,600/1,800/2,000 mm). The monitor section grows with 10/15/19 U, the PC section always has 18 U. Width 600 mm, depth 600 or 800 mm — special versions on request.
Can the SZE2 PC be actively cooled?
Yes — thanks to IP 54 it is sealed enough for a compressor cooling unit that maintains the degree of protection. With low power loss, a heat exchanger is often sufficient. The cooling capacity calculator gives you the required capacity in two minutes.
Is the SZE2 PC available in stainless steel?
Yes. Frame, doors, panels, roof and plinth can be made of stainless steel. The standard is powder-coated sheet steel in RAL 7035, special colours on request.