From plinth to wire mesh cable tray: the complete accessories range for SZB IT, DSR IT, Z-SERVER, SZE2 PC and the open racks SRD/SRX – more than 45 components in eight groups, with key data and catalogue page references. Assembled at the factory or supplied individually.

Request a quote Configure a cabinet with accessories

One range, eight groups – everything from the ZPAS catalogue

A 19″ cabinet is only as good as its fit-out: equipment shelves that really carry the load, blanking panels that direct the airflow, cable management that still keeps things tidy after the third conversion. ZPAS manufactures the complete accessories range for its own server cabinets and racks – here it is in full, grouped and with the key data from the catalogue. Each row links directly to the catalogue page with dimensional drawing and catalogue numbers (RAL 7035 light grey / RAL 9005 black).

With all versions and catalogue numbers – the three most requested groups have their own pages; ventilation is covered under climate control:

Plinths, castors & levelling feet

The base under the cabinet: the 100 mm high plinth is assembled from corners and panels for each side – for Z-SERVER, SZB IT and DSR IT, can be joined in a row and stacked up to four plinths high. If you want to move the cabinet, choose castors; if you need to align it on an uneven floor, levelling feet or levelling sets.

Plinth 100 mm – assembled from corners and panels
Plinth 100 mmassembled from corners and panels
Plinth corner – set of 4, with plastic cover
Plinth cornerset of 4, with plastic cover
Castor type 150 – with brake, castor set (4 pcs) max. 400 kg; SZB IT on type 150 max. 150 kg
Castor type 150with brake, 4 castors max. 400 kg – SZB IT on them max. 150 kg
Levelling feet – M12 × 38, set of 4
Levelling feetM12 × 38, set of 4
BASE · PLINTH SYSTEM

Plinth made of corners and panels

Each element is ordered individually: 4 plinth corners plus panels in the appropriate length – solid, perforated or with brush strip for cable entry. The panels can also be fitted and removed on a loaded cabinet; levelling set (0–10 mm) and vibration dampers can be retrofitted to the corners.

MOBILE · CASTORS

Castors type 150 and type 300

Type 150 (castor set max. 400 kg on 4 castors) for SZB IT and the open racks SRD/SRX; type 300 (castor set max. 600 kg) with support rails for SZB IT, DSR IT and SZE2 PC. The values apply to the castors only: an SZB IT may be loaded with max. 150 kg on type 150 castors and with max. 500 kg on type 300 castors. Each cabinet uses two castors with and two without a brake.

ComponentKey data / versionsCatalogue
Plinth panelssolid, perforated or with brush strip – lengths 400–1000 mm, can be fitted even on a loaded cabinetp. 78 →
Plinth cornersset of 4, height 100 mm, removable plastic coversp. 78 →
Plinth connection kitconnects plinths in a row or stacked (max. 4 × 100 mm)p. 79 →
Levelling sets for plinthsadjustment range 0–10 mm, versions for SZB IT/DSR IT and Z-SERVERp. 79 →
Vibration dampers10 mm rubber, set of 4 – e.g. for industrial buildingsp. 79 →
Levelling feetthread M12 × 38, set of 4 incl. lock nutsp. 80 →
Castors type 150for SZB IT, SRD, SRX – max. 400 kg on 4 castors (castors only; SZB IT on type 150: max. 150 kg), with/without brakep. 80 →
Castors type 300for SZB IT, DSR IT, SZE2 PC – with support rails, max. 600 kg on 4 castors (castors only; SZB IT on type 300: max. 500 kg)p. 81 →

Equipment shelves – 6 to 200 kg, neatly graded

Nine shelf types cover everything, from the switch to the UPS. The rule of thumb: two profile rails for light equipment, four profile rails for the standard load, six rails with side mounting for the heavyweights. All shelves come with mounting accessories, almost all optionally in RAL 7035 or RAL 9005.

II/2U – fixed – 2 profile rails, up to 25 kg
II/2U – fixed2 profile rails, up to 25 kg
IR/1U – pull-out – 4 profile rails, up to 30 kg
IR/1U – pull-out4 profile rails, up to 30 kg
Flexible shelf – adjustable depth, up to 150 kg
Flexible shelfadjustable depth, up to 150 kg
Heavy-duty shelf – fixed – side-mounted, up to 200 kg
Heavy-duty shelf – fixedside-mounted, up to 200 kg
All 27 equipment shelves with catalogue numbers →
LIGHT · 2 RAILS

Fixed and pull-out shelves

Mounted on the front profile rails only: 1 U shelves with 6–10 kg for patch panel levels, 2 U shelves, fixed (25 kg) in four usable depths from 250 to 650 mm – or pull-out (20 kg) for equipment that has to come forward for maintenance.

STANDARD · 4 RAILS

Shelves with adjustable brackets

Mounted at the front and rear, the rear brackets adjustable in length: IS/0.5U fixed (70 kg), ISU/1U with cable openings and cable guide ring (120 kg) for cabinet depths up to 1000 mm – and IR/1U pull-out (30 kg).

HEAVY · UP TO 200 KG

Flexible and heavy-duty shelves

The flexible 1 U shelves (150 kg) bridge freely adjustable depths of 350–600 or 500–900 mm. Above that: heavy-duty shelves on six rails, side-mounted – fixed 200 kg, pull-out 140 kg, for SZB IT and Z-SERVER with a depth of 1000/1200 mm.

ComponentKey data / versionsCatalogue
Equipment shelf II/1U fixedon 2 profile rails, usable depth 250/350 mm – 10/6 kgp. 82 →
Equipment shelf II/2U fixedon 2 profile rails, usable depth 250–650 mm – 25 kgp. 82 →
Equipment shelf II/2U pull-outon 2 profile rails, usable depth 355–555 mm – 20 kgp. 82 →
Equipment shelf IS/0.5U fixedon 4 profile rails, for cabinet depth 600–800 mm – 70 kgp. 83 →
Equipment shelf ISU/1U fixedwith cable openings + cable guide ring, cabinet depth 600–1000 mm – 120 kgp. 83 →
Equipment shelf IR/1U pull-outon 4 profile rails, cabinet depth 600–800 mm – 30 kgp. 83 →
Flexible equipment shelvesfreely adjustable depth 350–600 or 500–900 mm – 150 kgp. 84 →
Heavy-duty shelf, fixedside-mounted on 6 rails, for depth 1000/1200 mm – 200 kgp. 85 →
Heavy-duty shelf, pull-outside-mounted on 6 rails – 140 kgp. 85 →

19″ mounting hardware: profile rails, braces & more

The framework inside the cabinet: 19″ profile rails are available as type STANDARD (15 mm wide) and PREMIUM (12 mm) in heights from 18 to 47 U, plus middle profile rails as an additional installation level. In 600 mm wide cabinets the rails sit directly on the depth braces; in 800 mm wide cabinets offset brackets create the 19″ spacing. In SZE2 PC cabinets only 15 mm rails can be used; the profile rails for Z-SERVER and wall-mounted enclosures are listed with the respective series in the catalogue.

19″ profile rails – STANDARD 15 mm / PREMIUM 12 mm
19″ profile railsSTANDARD 15 mm / PREMIUM 12 mm
Offset brackets – for 800 mm wide cabinets
Offset bracketsfor 800 mm wide cabinets
Support rail – supports heavy equipment
Support railsupports heavy equipment
Fixing set – M6 screws and cage nuts
Fixing setM6 screws and cage nuts
SYSTEM · OVERVIEW

All elements working together

The exploded view in the catalogue shows how everything fits together: profile rails (1), middle rails (2), depth braces (3), offset brackets (4), support rails (5) and cross members (6). Plus mounting sets for rails and equipment – M6 screws, cage nuts, plastic washers.

ComponentKey data / versionsCatalogue
19″ profile railstype STANDARD (15 mm) and PREMIUM (12 mm), 18–47 Up. 87 →
Middle profile railsadditional installation level, prerequisite for heavy-duty shelvesp. 87 →
Depth bracesfor cabinet depths 600–1200 mm, carries profile rails, cable ducts and traysp. 87 →
Offset bracketscreate the 19″ spacing in 800 mm wide cabinets (zamak die-cast)p. 88 →
Mounting accessoriessets for profile rail mounting plus M6 screws + cage nuts for equipmentp. 88 →
19″ cross memberlength 500 mm, slots 6.5 × 22 mm – cable routing and equipment supportp. 88 →
Support railslengths 250/350/450/550/650 mm, slots 6.5 × 22 mm, support heavy equipmentp. 89 →
Adjustable support railsset of 2, adjustable 350–600 / 550–900 / 850–1150 mm, slots 12.5 × 25 mmp. 89 →

Baying, earthing & fittings

What turns the cabinet into a finished workplace: the lighting set (LED, optionally with door position switch – light on as soon as the door opens), the document pocket on the door, copper earthing bars horizontal and vertical including cable sets – and roofs that neatly cover the ventilation openings of SZB IT and SZE2 PC.

Lighting set – LED 230 V / 5 W, 1 U
Lighting setLED 230 V / 5 W, 1 U
Door position switch – light on when the door opens
Door position switchlight on when the door opens
Baying kit – connects two cabinets
Baying kitconnects two cabinets
Roof for SZB IT – 8 sizes, +40 mm height
Roof for SZB IT8 sizes, +40 mm height
LIGHT · LED SET

Lighting set with door switch

LED lamp 230 V / 5 W with switch on a 19″ sheet steel plate (1 U), mounted on the profile rails. The separate connecting cable with door position switch switches the light on when the door opens – for SZB IT and DSR IT.

FINISH · ROOF

Roofs for SZB IT and SZE2 PC

As a visual finish and cover for the ventilation openings: the roof for SZB IT in 8 sizes (600/800 mm wide, 600–1200 mm deep, +40 mm height) and for SZE2 PC in two sizes (+41.5 mm) – including fixings.

ComponentKey data / versionsCatalogue
Baying kit SZB IT / DSR ITconnects two cabinets via floor and roof platep. 90 →
Lighting setLED 230 V / 5 W with switch, 19″ mounting 1 Up. 90 →
Connecting cable with door position switchlight on when the door opens – for SZB IT/DSR ITp. 90 →
Document pocketA4, plastic, self-adhesive for door mountingp. 90 →
Copper earthing bar, horizontalCu 15 × 5 × 375 mm – alternative to the factory-fitted steel barp. 91 →
Copper earthing bars, verticalM5 or M6 thread, for 30/42/45/47 U, on profile rail or depth bracep. 91 →
Earthing cable sets6 mm² copper cables with ring terminals ø 6 mmp. 91 →
Roof for SZE2 PCcovers ventilation openings, +41.5 mm overall heightp. 92 →
Roof for SZB IT8 sizes (600/800 × 600–1200 mm), +40 mm overall heightp. 92 →

Blanking & covers – airflow under control

Open U positions and cable openings mean air leakage: 19″ blanking panels close free spaces (optionally tool-free with sealable connectors), plates with filter mat, brush or foam pass-through serve floor and roof openings, horizontal brushes and vertical blanking panels seal the front of SZB IT cabinets – important wherever cold air is to be directed precisely to the front of the equipment, for example in Databox containment.

19″ blanking panels – 1–6 U, with earthing stud
19″ blanking panels1–6 U, with earthing stud
Tool-free blanking panels – plastic connectors UL94-V0
Tool-free blanking panelsplastic connectors UL94-V0
Plate with brush pass-through – for floor and roof plate
Plate with brush pass-throughfor floor and roof plate
Brush panel – 1 U, pass-through 341 × 21.5 mm
Brush panel1 U, pass-through 341 × 21.5 mm
19″ LEVEL · BLANKING

Blanking panels 1–6 U

Made of sheet steel or aluminium with M5 earthing stud, mounted with cage nuts – or in the tool-free version with plastic connectors (flammability class UL94-V0), which can also be sealed.

SEALING · BRUSHES

Front sealing for the cold aisle

Horizontal brushes sit below and above the 19″ usable area; vertical blanking panels with brushes (3 versions, 42/45/47 U) close the gap between profile rail and side panel – so that cold air does not flow past the equipment.

ComponentKey data / versionsCatalogue
Plates for floor/roof plate and roofblank, perforated, filter mat, brush or foam pass-through – openings 380 × 380 and 380 × 210 mmp. 93 →
19″ blanking panels1–6 U, sheet steel or aluminium, with M5 earthing studp. 94 →
19″ blanking panels, tool-free1–6 U, plastic connectors (UL94-V0), sealablep. 94 →
Horizontal brushesseal the cabinet front – for width 600/800 mmp. 95 →
Vertical blanking panels with brushes3 versions for 42/45/47 U – seal the space between profile rail and side panelp. 95 →

Cable management – horizontal and vertical

Ten building blocks for orderly cabling: horizontally the cable management panels (with rings, with cable duct or as a brush panel with support plate for cable reserves), vertically cable ducts, wire mesh and sheet steel cable trays on the depth braces, plus economical PVC ducts with stiffening profile. The cable guide rings in seven sizes fit both panels and profile rails.

Cable management panel with cable duct – 1 U, removable front
Cable management panel with cable duct1 U, removable front
Cable guide rings – 7 sizes, on the panel or on the rail
Cable guide rings7 sizes, on the panel or on the rail
Vertical cable duct – 100 × 111 mm, 42–47 U
Vertical cable duct100 × 111 mm, 42–47 U
Wire mesh cable tray – 150 × 15 mm, up to 2000 mm
Wire mesh cable tray150 × 15 mm, up to 2000 mm
Cable management with all catalogue numbers →
SYSTEM · OVERVIEW

All elements working together

The catalogue drawing shows the positions in the cabinet: cable guide rings (1), cable management panel (2), brush panels (3/4), cable guide bar (5), sheet steel cable tray (6), wire mesh cable tray mounted inside/outside (7) and vertical cable duct (8).

VERTICAL · DUCT

Vertical cable routing

The vertical cable duct (100 × 111 mm, 42–47 U) with removable front for 800 mm wide SZB IT; slimmer: the wire mesh cable tray (15.5 mm deep – fits next to the depth brace) or the sheet steel cable tray (30 mm deep), both up to 2000 mm long.

ComponentKey data / versionsCatalogue
Cable guide rings7 sizes from 44 × 44 to 88 × 88 mm or 44 × 110 mm, sets of 5, black on requestp. 97 →
Cable management panel for cable guide rings1 U, with mounting holes and rubber blanking plugsp. 97 →
Cable management panels with cable duct1 or 2 U, removable front cover, cable cut-outs at the rearp. 98 →
Cable management panels with rings1 U, 5 or 9 rings, also with brush sealp. 99 →
Cable guide barlengths 210–500 mm, between front and rear profile railsp. 99 →
Brush panels1 U, cable opening 341 × 21.5 mm – without or with support plate (300 mm) for cable reservesp. 100 →
Vertical cable duct100 × 111 mm for 42/45/47 U – for 800 mm wide SZB IT, removable frontp. 100 →
Wire mesh cable tray150 × 15.5 mm, lengths 1100–2000 mm (24–47 U) – fits next to the depth bracep. 101 →
Sheet steel cable tray150 × 30 mm, lengths 1100–2000 mm, galvanised sheet steelp. 101 →
PVC cable ducts + C-profile2 m sections, 40/60 mm wide, with stiffening C-profile (15–47 U)p. 102 →

Ventilation & thermostats

Passive heat removal for network and server cabinets: 19″ fan units with two to four fans in 1 U, roof fan units for the openings in the roof plate, the compact PW-3U3 with 3 U – and thermostats and a hygrostat for the DIN rail, which switch the fans on only when needed. How much air a cabinet needs is shown on the page Server rack climate control, with a calculator.

19″ fan unit PW-1.3T – 3 fans, 1 U, 495 m³/h
19″ fan unit PW-1.3T3 fans, 1 U, 495 m³/h
Roof fan unit PWD-4W – 4 fans, also with thermostat
Roof fan unit PWD-4W4 fans, also with thermostat
Fan unit PW-3U3 – 3 U, 490 m³/h
Fan unit PW-3U33 U, 490 m³/h
Thermostat – normally open or normally closed, for DIN rail
Thermostatnormally open or normally closed, for DIN rail
ComponentKey data / versionsCatalogue
19″ fan units PW1 U with 2, 3 or 4 fans – 330, 495 or 660 m³/h, switch for continuous or thermostat operation (thermostat separate)p. 106 →
Roof fan units PWD2 or 4 fans in the roof plate, optionally with thermostatp. 107 →
Fan unit PW-3U33 U, 3 fans, 490 m³/h, RAL 9005 – further units can be connectedp. 108 →
Thermostats & hygrostatNormally open (fans) or normally closed (heating), hygrostat against condensation – DIN rail mountingp. 109 →
Size ventilation and climate control →

Power strips, PDUs & power distribution

Distribute, measure and monitor power: basic power strips for 19″ with Schuko or UTE sockets (16 A, optionally with surge protection and filter), Smart PDUs up to 32 A with energy metering at the input or per socket, remote switching and environmental sensors – plus mounting brackets for vertical mounting and the PS-3U power distribution panel for DIN-rail-mounted devices.

Power strip LZ-211 – 6 × Schuko, illuminated switch
Power strip LZ-2116 × Schuko, illuminated switch
Smart PDU with IEX – C14 and C20 plugs, lockable
Smart PDU with IEXC14 and C20 plugs, lockable
Advanced Controller – SNMP, 2 × Gigabit, hot-swap
Advanced ControllerSNMP, 2 × Gigabit, hot-swap
Power distribution panel PS-3U – 3 U, DIN rail, 22 modules
Power distribution panel PS-3U3 U, DIN rail, 22 modules
ComponentKey data / versionsCatalogue
Basic PDU LZ-30/9, LZ-211, LZ-30F19″/1 U, 230 V, 16 A – 6 or 9 sockets (Schuko/UTE), illuminated switch, surge protection + filterp. 114 →
Smart PDU7 specification levels (B to POMS), C13/C19/IEX/Schuko/UTE, single- and three-phase up to 32 A, SNMP/Modbusp. 115 →
LZ holder / LZ mounting bracketvertical mounting on SRD/SRX or in 800 mm wide SZB IT (42/45/47 U)p. 123 →
Power distribution panel PS-3U3 U, 35 mm DIN rail for 22 DIN-rail-mounted devices, empty or fittedp. 124 →
Power strips & PDUs in detail →

IT solutions catalogue (PDF, 120 pages) – the complete accessories chapter with all dimensional drawings and catalogue numbers on pages 67–114.
Open catalogue (PDF) → · all catalogues in the download centre

Frequently asked questions – 19″ accessories

Which cabinets does the 19″ accessories range fit?

The range is designed for the ZPAS series SZB IT, DSR IT, Z-SERVER and SZE2 PC, the open racks SRD/SRX, the SJB office network cabinet and the Z-BOX/Z-CUBE wall-mounted enclosures – the matching series is stated for each component. The 19-inch dimensions themselves are standardised (1 U = 44.45 mm), so many components such as blanking panels or cable management panels fit any 19″ cabinet.

How much load can the equipment shelves carry?

Neatly graded from 6 kg to 200 kg static distributed load: light 1 U shelves on two profile rails up to 10 kg, 2 U shelves up to 25 kg, shelves on four profile rails up to 120 kg, flexible shelves with adjustable depth up to 150 kg – and side-mounted heavy-duty shelves on six rails up to 200 kg.

Does ZPAS also supply the accessories fully assembled?

Yes – in the server rack configurator, equipment shelves, blanking panels, lighting and cable management can be ordered directly with the cabinet, which is delivered fitted out from the factory. Individual components are supplied with mounting accessories; most sheet steel parts are available in RAL 7035 (light grey) and RAL 9005 (black).