DSR IT
colocation server rack

One rack, several tenants: partition floors divide the DSR IT into 2 or 4 autonomous compartments — each with its own 19″ mounting rails, its own cable ducts, a perforated door and its own key. Usable 40–46 U (frame 1963/2186 mm), 600/800 × 1000/1200 mm, bayable and suitable for Data Box containment. Direct from the manufacturer.

Request a quote Configure DSR IT
2 or 4
autonomous compartments
40–46 U
usable · frame 1963/2186 mm
600 / 800
Width in mm
1000 / 1200
Depth in mm
80 %
Door open area

The DSR IT is the ZPAS colocation server rack: a 19″ floor-standing rack divided by partition floors into 2 or 4 autonomous compartments — each with its own mounting rails, its own cable ducts and its own key. Usable 40–46 U (frame 1963/2186 mm), 600/800 × 1000/1200 mm, perforated doors, IP 20 according to EN 60529, from the manufacturer.

🔐 Configure DSR IT nowHeight, dimensions, compartments, doors & accessories — selectable in the server rack configurator · no obligation →

One rack, several tenants — physically separated

In colocation data centres, several customers share the infrastructure — but nobody may access anyone else’s equipment. The DSR IT solves this mechanically rather than organisationally: horizontal partition floors divide the rack into autonomous compartments. Each compartment has its own 19″ mounting rails at the front and rear (STANDARD type, depth-adjustable, with U markings), independent cable ducts along the left and right sides of the rack and a perforated door with its own key. Cable entry is either from below or from above — cable openings in the floor and roof plates are closed with knock-out blanks.

Version table: sizes and compartment layout

Two heights, each with two compartment variants — all width/depth combinations (600/800 × 1000/1200 mm) are available. Source: ZPAS IT catalogue.

VersionRack 1,963 mmRack 2,186 mm
Frame height H1,963 mm2,186 mm
2 compartments2 × 20 U = 40 U usable2 × 23 U = 46 U usable
4 compartments4 × 10 U = 40 U usable4 × 11 U = 44 U usable
Width × depth600/800 × 1000/1200 mm — all combinations

The version number is the core of the catalogue number W-DIT-​XXXXXX-​44XX-​XX-​XXX — front/rear doors always perforated (code 44), then side panels (0/A/D), number of compartments (2/4), cable tray routing (1–3) and colour (011/161); all codes are defined in the catalogue on p. 41: · 🧊 3D model on 3Dfindit ↗ All series and dimensions compared: server rack dimensions 42, 45 and 47 U.

Width [mm]Depth [mm]42 U (H 1963)47 U (H 2186)
6001000426010476010
6001200426012476012
8001000428010478010
8001200428012478012

Usable space per compartment: 2 compartments = 2 × 20 U (42 U) or 2 × 23 U (47 U), 4 compartments = 4 × 10 or 4 × 11 U. Ordering key: IT Solutions catalogue p. 41 (PDF) → · 🧊 3D model on 3Dfindit ↗

Standard equipment from the factory

Fully dismountable rack frame: floor plate, roof plate, four frame profiles
One partition floor (2 compartments) or three partition floors (4 compartments)
Perforated front and rear doors for each compartment — 80% open area, each compartment with a different key
Two pairs of STANDARD-type 19″ mounting rails per compartment, depth-adjustable, with U markings
Autonomous cable ducts on the left and right, side panels or partition walls depending on the configuration
Door opening angle up to 270°, reversible door hinges
Earthing bar and earthing cables for doors and side panels
Levelling feet — or installation directly on the floor (no protruding parts)
Bayable — can also be built as a Data Box (cold aisle/hot aisle containment)

Plinths, type 300 castors, equipment shelves and cable management: the complete 19″ accessories range also fits the DSR IT — each component with series assignment and catalogue page reference.

From colocation rack to contained row

DSR IT racks can be bayed and, like the Z-SERVER, contained as a Data Box: roofs, sliding doors and seals turn the row of racks into a closed cold or hot aisle — tenant separation and cooling efficiency in one. Complete concepts with containment, cooling and monitoring: data centre & server room solutions. The cooling capacity calculator quantifies the cooling load per compartment according to IEC 60890.

Material & finish

Rack frame, side panels, partition floors, doors, mounting rails and cable trays made of sheet steel, powder-coated in RAL 7035 (light grey) or RAL 9005 (black); brackets of the 800 mm width made of zamak die-cast. Degree of protection IP 20 according to EN 60529.

Frequently asked questions — DSR IT

How does the compartment separation work?

Partition floors divide the rack into 2 or 4 autonomous compartments. Each has its own 19″ mounting rails at the front and rear, independent cable ducts on the left/right and a perforated door with its own key — tenants can only reach their own equipment.

Which sizes and compartment layouts are available?

Frame 1,963 mm: usable 40 U (2 × 20 or 4 × 10 U). Frame 2,186 mm: usable 46 U (2 × 23) or 44 U (4 × 11) — the partition floors take up some usable height. Widths 600/800 mm, depths 1000/1200 mm, all combinations available.

Who is the DSR IT intended for?

For colocation data centres and operators who rent out one rack to several tenants or need to physically separate customer segments — from the regional colo provider to the campus network with separate departments.

Can the DSR IT be contained?

Yes — DSR IT rows can be built as a Data Box (cold aisle/hot aisle containment). The racks are bayable and stand either on levelling feet or directly on the floor.

All server rack questions in the FAQ →

Product images

DSR IT — compartments & design

ZPAS DSR IT colocation server rack with 4 separately lockable compartments
DSR IT with 4 compartments — every door perforated and individually lockable.
ZPAS DSR IT opened – 4 compartments with partition floors and their own mounting rails
Opened: partition floors separate the compartments, each with its own 19″ mounting rails.
ZPAS DSR IT side view with opened compartments and cable ducts
Side view: autonomous cable ducts run separately up/down for each compartment.
ZPAS DSR IT variants with 2 and 4 compartments side by side
Variants: 2 or 4 compartments — in 42 and 47 U, widths 600/800 mm.
ZPAS DSR IT detail of partition floor and compartment door from the inside
Detail: partition floor as a physical separation between two compartments.
ZPAS DSR IT rack row as a Data Box cold aisle containment
DSR IT row as a Data Box: cold aisle containment with sliding doors and roof.

DSR IT direct from the manufacturer

From a single rack to a contained colocation row — technical advice from Leipzig included.

Configure DSR IT → Request a quote