Z-SERVER
Premium server rack

The flagship for data centres, server rooms and AI infrastructure: 42/45/47 U, depths 1000/1200 mm, static load capacity 1,600 kg on levelling feet – up to 2,000 kg without levelling feet. Doors with 86 % perforated area for maximum airflow, as the basis of the Z-SERVER BOX cold aisle/hot aisle containment. Direct from the manufacturer.

Request a quote Configure Z-SERVER
42/45/47 U
Frame 2000–2200 mm
600 / 800
Width in mm
1000 / 1200
Depth in mm
1,600–2,000 kg
Load capacity (static)
86 %
Door perforation

The Z-SERVER is ZPAS’s premium 19″ server rack for data centres and server rooms: high-strength, dismountable frame made of steel profiles with 42–47 U, depths 1000/1200 mm, a static load capacity of 1,600 kg on levelling feet or 2,000 kg without levelling feet, and perforated doors (86 % of the surface, 80 % air permeability) – the basis of the Z-SERVER BOX cold aisle containment.

Configure your Z-SERVER nowHeight, dimensions, doors, cooling & accessories – selectable in the server rack configurator · no obligation →

Built for heavy loads: data centres, AI and GPU

Modern servers are getting heavy: GPU systems, UPS and cooling components quickly add up to 800–1,200 kg per rack. The Z-SERVER carries 1,600 kg on levelling feet and 2,000 kg without levelling feet, standing directly on the floor (mounting rails 50–150 mm from the front/rear, evenly distributed load). If heavy equipment is installed on movable sliding rails, the retrofittable reinforcement kit is recommended. The door perforation takes care of the air supply: 86 % of the door surface, 80 % air permeability – the servers draw in cool air without obstruction.

Version table: all available sizes

Three heights, two widths, two depths – with the Z-SERVER every combination is available (12 versions). Source: ZPAS IT catalogue.

Depth ↓ / height →42 U45 U47 U
1000 mm (W 600/800)✓✓✓
1200 mm (W 600/800)✓✓✓
Frame height H2,000 mm2,100 mm2,200 mm

Each size has a six-digit version number – it forms the core of the catalogue number W-ZS-​XXXXXX-​XX00-​2-​XXX (front and rear door: 1 = single, 2 = double, both perforated · colour: 011 = RAL 7035, 161 = RAL 9005; the structure is defined in the catalogue on p. 11, PDF in English): · 3D model on 3Dfindit ↗ All series and dimensions compared: server rack dimensions 42, 45 and 47 U.

Width [mm]Depth [mm]42 U (H 2000)45 U (H 2100)47 U (H 2200)
6001000426010456010476010
6001200426012456012476012
8001000428010458010478010
8001200428012458012478012

Version numbers and ordering key: IT solutions catalogue, p. 10 (PDF) → · 3D model on 3Dfindit ↗

Build your catalogue number

Choose size, doors and colour – this produces the complete catalogue number according to the ordering key in the ZPAS catalogue.

Standard equipment ex works

High-strength, dismountable rack frame made of closed steel profiles
Perforated front and rear door, each single or double-leaf
Roof plate with perforation and knock-out covers
Two pairs of 19″ mounting rails, PREMIUM type – infinitely adjustable without tools, with U numbering
Multi-point locking: 5-point (single door), 3-point (double door, upgradable to 5-point) – locks with access control possible
Door opening angle up to 270°, reversible door hinge
Conversion from 19″ to 21″ without additional parts (at 800 mm width)
Earthing cables for doors, roof plate and mounting rails · levelling feet

The split side panels (type A/B, easy installation) are not part of the standard equipment: like the other accessories, they are ordered separately; partition walls can be retrofitted at any time.

From the plinth and heavy-duty equipment shelves (up to 200 kg on six rails) to tool-free blanking panels: the complete 19″ accessories range fits the Z-SERVER and can be supplied factory-fitted on request.

System accessories: made for the Z-SERVER

In addition to the general 19″ accessories, there are parts made to fit the Z-SERVER frame exactly – depending on the part for 42, 45 and 47 U, 600 or 800 mm width and 1000 or 1200 mm depth, painted parts in RAL 7035 or RAL 9005. The components of the cold aisle containment (sliding doors, roof modules, add-on cabinets, lighting) are shown on the Databox page.

AreaAccessoryCatalogue (PDF)
Side panelsHorizontally split side panel type A (flat, +3 mm per side, door opening up to 270°) or type B (deep, +11 mm per side – at 600 mm width, room for a power strip next to the mounting rail) · flush side panel, recessed into the framep. 13
partitionBetween bayed cabinets, eight cable openings 150 × 45 mm with knock-out covers, only 2 mm gap between the cabinetsp. 14
Baying & doorCabinet baying kit (four connectors per pair of cabinets) · retrofit kit for double doors: from 3-point to 5-point lockingp. 15
Airflow managementVertical blanking panels between the 19″ level and the side panel, horizontal ones towards the roof and floor plate – no warm air flowing back to the frontp. 16
Roof & floorBrush strip for the roof plate · floor plate with brush entry, solid or with knock-out cover · lateral brush strips (800 mm width)p. 17
Castors & sealingCastor sets, swivel and fixed (1,500 kg) · sealing strip at the bottom so that no cold air escapes from the cold aislep. 18
Cable routingVertical cable comb (600 and 800 mm width) · vertical cable duct with cover for high cable density (800 mm) · patch panels with cable duct, 1 and 2 Up. 19
OrganisersVertical (800 mm width) and horizontal organisers for fixing cables or power strips · centre mounting railp. 20
Reinforcement & earthingReinforcement kit for heavy equipment on sliding rails · earthing bars made of copper or galvanised steel with M5 threadsp. 21
Above the cabinetCable tray supports, centre (across two cabinets in depth) and lateral (above the first or last cabinet)p. 27
Power stripsSingle or double brackets, for one or two power stripsp. 28

Z-SERVER BOX: from rack to cold aisle containment

The Z-SERVER is designed as a system: with roofs, sliding doors and seals, rows of racks are joined to form the Z-SERVER BOX cold aisle/hot aisle containment – cool supply air and warm exhaust air remain separated, and the energy required for cooling drops significantly. In addition, there are airflow components inside the rack, cable management and mounting parts for power strips (PDU). The Databox product page shows all components of the containment with their catalogue numbers. Complete data centre concepts with containment, cooling and monitoring: data centre & server room solutions. For high-load applications: server racks for AI & GPU.

It also works the other way round, one size smaller: with air conditioning, UPS installation space, access control and monitoring, a single Z-SERVER becomes a micro data centre – the edge data centre in a rack for sites without their own server room.

Cooling in and on the rack

In an air-conditioned data centre, room cooling does the work – the Z-SERVER provides the airflow with 86 % door perforation. At higher densities, cold aisle containment and close-coupled cooling complement this; with closed doors (IP 54/55), active side-mounted cooling units CVE and roof-mounted cooling units ETE are also possible – selectable directly in the configurator. The server rack cooling page gives an overview of all cooling levels; the cooling capacity calculator gives you the required cooling capacity in seconds.

Surface & material

Sheet steel; side panels, doors and roof plate powder-coated in RAL 7035 (light grey) or RAL 9005 (black), mounting rails and metal parts galvanised. Degree of protection according to EN 60529 depending on the door variant: IP 20 with perforated doors, IP 54/55 with closed doors.

The industry page racks for AI & GPU infrastructure shows it in heavy-duty use.

Frequently asked questions – Z-SERVER

What sizes does the Z-SERVER come in?

Three heights: 42, 45 and 47 U (frame heights 2000/2100/2200 mm), widths 600/800 mm, depths 1000/1200 mm – all 12 combinations available.

Why is the Z-SERVER suitable for AI and GPU racks?

Because of its load capacity: static 1,600 kg on levelling feet, 2,000 kg without levelling feet – GPU servers including UPS quickly reach 800–1,200 kg per rack. In addition, 86 % door perforation and, for heavy equipment on sliding rails, a reinforcement kit that can be retrofitted. More in the AI & GPU guide.

What is the Z-SERVER BOX?

The cold aisle/hot aisle containment based on the Z-SERVER: rows of racks are joined into a closed aisle with roofs, sliding doors and seals – this significantly reduces the energy required for cooling. Details: data centre solutions.

Can I convert an 800 mm wide rack from 19 to 21 inches?

Yes – on 800 mm wide racks the spacing can be changed from 19 to 21 inches without additional mounting parts. The PREMIUM mounting rails are infinitely adjustable without tools.

All questions about server racks in the FAQ →

Product images

Z-SERVER – versions & details

ZPAS Z-SERVER server racks in black – closed and with the perforated door open
Z-SERVER in RAL 9005 – closed and with the perforated front door open.
ZPAS Z-SERVER open – 19-inch PREMIUM mounting rails and perforated doors
A look inside the rack: PREMIUM mounting rails, split side panels, perforated doors.
ZPAS Z-SERVER perforated double rear door with 3-point locking
Perforated double rear door – space-saving in the aisle, upgradable to 5-point locking.
ZPAS Z-SERVER detail of the 5-point locking on the perforated door
Detail: 5-point locking system with swing handle – access control possible.
ZPAS Z-SERVER detail of the roof plate with perforation and knock-out covers
Roof plate detail: perforation and knock-out covers for cable entry.
ZPAS Z-SERVER BOX cold aisle containment made of Z-SERVER rack rows
Z-SERVER BOX: rows of racks as cold aisle/hot aisle containment in the data centre.

Z-SERVER direct from the manufacturer

From a single rack to a contained data centre row – technical advice from Leipzig included.

Configure Z-SERVER → Request a quote