Accessories for electrical enclosures
Doors, panels, roof, plinths

Doors in sheet steel, with viewing window or passive ventilation, side panels and partition walls, roofs, roof and floor plates, plinths, castors and lifting eyes for the SZE2 and SZE3 – every size with a catalogue number.

Request a quote Configure electrical enclosure

Which part fits which enclosure?

For these accessories the enclosure size decides: doors depend on height and width, side panels and partition walls on height and depth, roofs and plinths on width and depth. The tables below are therefore sorted by these dimensions – find the enclosure size, read off the catalogue number. A click on the number opens the enquiry with this number.

The parts are available for both series, but they are not interchangeable: the SZE2 is welded, the SZE3 is bolted and symmetrical in design – its door can be fitted at the front, rear or side. Common to both series are the plinth corners, vibration dampers and the plinth connecting set, the roof and floor plates, the single lifting eye and the plinth panels for 600 to 1200 mm plinth length.

Doors: sheet steel, viewing window, passive ventilation

As standard the SZE2 and SZE3 have a sheet steel door with a double-bit lock and no handle. Three further versions are available as accessories: the glazed door with a pane of clear toughened glass, the door with passive ventilation (plastic ventilation grille, IP 54) and – single-leaf – the combination of both. Doors up to 800 mm width are single, for enclosures 1000 and 1200 mm wide they are double. The complete door leaf is supplied with hinges and lock; the material is powder-coated sheet steel in RAL 7035 with a stiffening frame of galvanised profiles (not on glazed doors).

  • SZE2: The door replaces the front door or the rear sheet panel, opening angle max. 120°. Solid and glazed door IP 54/55, ventilated doors IP 54.
  • SZE3: Thanks to the symmetrical frame, the door sits at the front, rear or side. Foamed-in PU seal, earthing stud M8, 4-point lock outside the sealing area – the lock does not affect the degree of protection. Opening angle max. 150°. Solid and glazed door IP 55, ventilated doors IP 54. On request ZPAS makes cut-outs, for example for operator panels, or external hinges for a larger opening angle.
Single doors – solid, glazed, ventilated, glazed + ventilated
Single doorsSolid, glazed, ventilated, glazed + ventilated
Double door – for 1000 and 1200 mm width
Double doorFor 1000 and 1200 mm width
Door stay – with catch, protects the hinges
Door stayWith catch, protects the hinges
Swing handle – instead of the double-bit lock
Swing handleInstead of the double-bit lock

SZE2: single doors

VersionHinge side2000 × 600 mm2000 × 800 mm2200 × 600 mm2200 × 800 mm
Door size H × W1990 × 5931990 × 7932190 × 5932190 × 793
Sheet steel door · IP 54/55right/leftW-1951-10-02-011W-1951-10-01-011W-4950-03-02-011W-4950-03-01-011
Glazed door · IP 54/55right/leftW-1951-F2-02-011W-1951-F2-01-011W-4950-96-02-011W-4950-96-01-011
Passively ventilated · IP 54rightW-1951-40-02-011W-1951-40-01-011W-4950-16-02-011W-4950-16-01-011
Passively ventilated · IP 54leftW-1951-40-10-011W-1951-40-09-011W-4950-16-04-011W-4950-16-03-011
Glazed door, passively ventilated · IP 54rightW-1951-F4-02-011W-1951-F4-01-011W-4950-18-02-011W-4950-18-01-011
Glazed door, passively ventilated · IP 54leftW-1951-F4-10-011W-1951-F4-09-011W-4950-18-04-011W-4950-18-03-011

SZE2: double doors

VersionHinge side2000 × 1000 mm2000 × 1200 mm2200 × 1000 mm2200 × 1200 mm
Door size H × W1990 × 493 / 519,51990 × 593 / 619,52190 × 493 / 519,52190 × 593 / 619,5
Sheet steel door · IP 54/55right leafW-1951-15-02-011W-1951-15-01-011W-4950-10-02-011W-4950-10-01-011
Sheet steel door · IP 54/55left leafW-1951-13-02-011W-1951-13-01-011W-4950-08-02-011W-4950-08-01-011
Glazed door · IP 54/55right leafW-1951-F6-02-011W-1951-F6-01-011W-4950-84-02-011W-4950-84-01-011
Glazed door · IP 54/55left leafW-1951-F8-02-011W-1951-F8-01-011W-4950-84-04-011W-4950-84-03-011
Passively ventilated · IP 54right leafW-1951-59-02-011W-1951-59-01-011W-4950-F3-02-011W-4950-22-01-011
Passively ventilated · IP 54left leafW-1951-57-02-011W-1951-57-01-011W-4950-F1-02-011W-4950-20-01-011

Double doors are ordered per leaf (packing unit 1 pc. = 1 leaf); right and left as seen from the front of the enclosure. Door size for double doors: height × width of right / left leaf.

SZE3: single doors

VersionHinge side2000 × 600 mm2000 × 800 mm2200 × 600 mm2200 × 800 mm
Door size H × W1990 × 5951990 × 7952190 × 5952190 × 795
Sheet steel door · IP 55right/leftW-6282-30-04-011W-6282-30-03-011W-6282-30-02-011W-6282-30-01-011
Glazed door · IP 55right/leftW-6282-A4-04-011W-6282-A4-03-011W-6282-A4-02-011W-6282-A4-01-011
Passively ventilated · IP 54rightW-6282-74-04-011W-6282-74-03-011W-6282-74-02-011W-6282-74-01-011
Passively ventilated · IP 54leftW-6282-74-10-011W-6282-74-09-011W-6282-74-08-011W-6282-74-07-011
Glazed door, passively ventilated · IP 54rightW-6282-A6-04-011W-6282-A6-03-011W-6282-A6-02-011W-6282-A6-01-011
Glazed door, passively ventilated · IP 54leftW-6282-A6-10-011W-6282-A6-09-011W-6282-A6-08-011W-6282-A6-07-011

SZE3: double doors

VersionHinge side2000 × 1000 mm2000 × 1200 mm2200 × 1000 mm2200 × 1200 mm
Door size H × W1990 × 495 / 5381990 × 595 / 6382190 × 495 / 5382190 × 595 / 638
Sheet steel door · IP 55right leafW-6282-45-04-011W-6282-45-03-011W-6282-45-02-011W-6282-45-01-011
Sheet steel door · IP 55left leafW-6282-47-04-011W-6282-47-03-011W-6282-47-02-011W-6282-47-01-011
Glazed door · IP 55right leafW-6282-D3-04-011W-6282-D3-03-011W-6282-D3-02-011W-6282-D3-01-011
Glazed door · IP 55left leafW-6282-D5-04-011W-6282-D5-03-011W-6282-D5-02-011W-6282-D5-01-011
Passively ventilated · IP 54right leafW-6282-85-04-011W-6282-85-03-011W-6282-85-02-011W-6282-85-01-011
Passively ventilated · IP 54left leafW-6282-87-04-011W-6282-87-03-011W-6282-87-02-011W-6282-87-01-011

Packing unit 1 pc. (per leaf for double doors). Ventilation is provided by plastic ventilation grilles with IP 54.

Door stay and swing handle

The door stay holds the open door in position and protects the hinges; it is fixed to the stiffening frame of the door and to the enclosure frame and can therefore not be fitted to glazed doors. When retrofitting to the SZE2, two holes of 6 mm diameter are drilled at the pre-marked positions. Instead of the double-bit lock there is a swing handle: on the SZE2 handle and profile half-cylinder are ordered separately, on the SZE3 the handle comes complete with insert and keys – without the locking parts on the inside of the door.

ComponentKey dataSZE2SZE3
Door staygalvanised sheet steel, with catch and fixing partsW-1951-32-00-000W-6935-17-00-000
Swing handle without insertPlastic, insert separateM1H-01-0024–
Profile half-cylinder for swing handlewith 1 keyM1H-02-0028–
Swing handle with double-bit insertPlastic housing, metal lever, 1 key–M1H-00-0532
Swing handle with profile half-cylinderPlastic housing, metal lever, 2 keys–M1H-00-0531
📄 Dimensional drawings in the catalogue: SZE2 p. 27–28 → · SZE3 p. 73–74 →
Request with the enclosure →Configure the complete enclosure: in the configurator → · Catalogue number: SZE3 · SZE2

Side panels and partition walls

Side panels are supplied in pairs, made of powder-coated sheet steel in RAL 7035, with foamed-in PU seal and threaded studs for the earthing conductors. The SZE2 has two designs: flush – the panel stays within the frame width and can serve as a partition in the enclosure row – and protruding, which widens the enclosure by 25 mm per side. On the SZE3 the side panel is bolted to the frame via spacers that position it; it adds 5 mm per side. To order, the side panels are given cut-outs for ventilation grilles, filter fans, heat exchangers or cooling units.

The partition wall made of galvanised sheet steel separates bayed enclosures without increasing the width – on the SZE2 it is fixed like the flush side panel, on the SZE3 it sits inside the frame. On the SZE3 ZPAS makes any openings to order, for example for cable entries.

SZE2 side panels – flush on the left, protruding on the right (+25 mm)
SZE2 side panelsFlush on the left, protruding on the right (+25 mm)
Partition wall – galvanised, separates bayed enclosures
Partition wallGalvanised, separates bayed enclosures
Rack depthSZE2 side panels, flushSZE2 side panels, protrudingSZE2 partition wallSZE3 side panelsSZE3 partition wall
Enclosure height 2000 mm
400 mmW-1951-09-13-011W-1951-07-29-011W-1951-31-13-000W-6282-18-08-011W-6282-98-08-000
500 mmW-1951-09-03-011W-1951-07-07-011W-1951-31-03-000W-6282-18-07-011W-6282-98-07-000
600 mmW-1951-09-02-011W-1951-07-06-011W-1951-31-02-000W-6282-18-06-011W-6282-98-06-000
800 mmW-1951-09-01-011W-1951-07-05-011W-1951-31-01-000W-6282-18-05-011W-6282-98-05-000
Enclosure height 2200 mm
400 mm–––W-6282-18-04-011W-6282-98-04-000
500 mmW-4950-65-03-011W-4950-24-07-011W-4950-25-03-000W-6282-18-03-011W-6282-98-03-000
600 mmW-4950-65-02-011W-4950-24-06-011W-4950-25-02-000W-6282-18-02-011W-6282-98-02-000
800 mmW-4950-65-01-011W-4950-24-05-011W-4950-25-01-000W-6282-18-01-011W-6282-98-01-000

Side panels: packing unit 2 pcs (1 pair) with fixing parts; partition wall: 1 pc. For the SZE2 with 2200 mm height there is no 400 mm deep version.

📄 Dimensional drawings in the catalogue: SZE2 p. 28 → · SZE2 p. 52 → · SZE3 p. 75 →
Request with the enclosure →Configure the complete enclosure: in the configurator → · Catalogue number: SZE3 · SZE2

Roof and top cover

The full roof made of powder-coated sheet steel (RAL 7035) is fitted with four spacer sleeves; the fixing screws M12 are supplied with the enclosure. On the SZE2 it raises the enclosure by 41.5 mm, leaving an air gap of 5 mm under the roof. The roof is available in two widths – matching the flush side panel at frame width, matching the protruding side panel 50 mm wider. The perforated roof of the SZE2 rests directly on the frame and raises the enclosure by 70 mm. On the SZE3 the roof including spacer sleeves adds 41 mm in height.

For the SZE3 there is, instead of the full top cover, the top cover with opening: with foamed-in seal and a cut-out for a roof plate (see below) or a fan panel for the roof.

Full roof – with 4 spacer sleeves, +41.5 mm (SZE2)
Full roofWith 4 spacer sleeves, +41.5 mm (SZE2)
Perforated roof – SZE2, +70 mm
Perforated roofSZE2, +70 mm
Top cover with opening – SZE3, 380 × 210 / 380 × 380 mm
Top cover with openingSZE3, 380 × 210 / 380 × 380 mm
Rack depthSZE2 roof for flush side panelsSZE2 roof for protruding side panelsSZE3 roofSZE3 top cover with openingOpening
Enclosure width 600 mm
400 mmW-1951-27-14-011W-1951-28-14-011W-6935-56-16-011W-6282-53-16-011380 × 210 mm
500 mmW-1951-27-13-011W-1951-28-13-011W-6935-56-15-011W-6282-53-15-011380 × 210 mm
600 mmW-1951-27-12-011W-1951-28-12-011W-6935-56-14-011W-6282-53-14-011380 × 380 mm
800 mmW-1951-27-11-011W-1951-28-11-011W-6935-56-13-011W-6282-53-13-011380 × 380 mm
Enclosure width 800 mm
400 mmW-1951-27-10-011W-1951-28-10-011W-6935-56-12-011W-6282-53-12-011380 × 210 mm
500 mmW-1951-27-09-011W-1951-28-09-011W-6935-56-11-011W-6282-53-11-011380 × 210 mm
600 mmW-1951-27-08-011W-1951-28-08-011W-6935-56-10-011W-6282-53-10-011380 × 380 mm
800 mmW-1951-27-07-011W-1951-28-07-011W-6935-56-09-011W-6282-53-09-011380 × 380 mm
Enclosure width 1000 mm
400 mm––W-6935-56-08-011W-6282-53-08-011380 × 210 mm
500 mmW-1951-27-06-011W-1951-28-06-011W-6935-56-07-011W-6282-53-07-011380 × 210 mm
600 mmW-1951-27-05-011W-1951-28-05-011W-6935-56-06-011W-6282-53-06-011380 × 380 mm
800 mmW-1951-27-04-011W-1951-28-04-011W-6935-56-05-011W-6282-53-05-011380 × 380 mm
Enclosure width 1200 mm
400 mm––W-6935-56-04-011W-6282-53-04-011380 × 210 mm
500 mmW-1951-27-03-011W-1951-28-03-011W-6935-56-03-011W-6282-53-03-011380 × 210 mm
600 mmW-1951-27-02-011W-1951-28-02-011W-6935-56-02-011W-6282-53-02-011380 × 380 mm
800 mmW-1951-27-01-011W-1951-28-01-011W-6935-56-01-011W-6282-53-01-011380 × 380 mm

SZE2: perforated roof

Cabinet widthRack depthCatalogue number
600 mm600 mmW-8215-A0-10-011
600 mm800 mmW-8215-A0-08-011
800 mm600 mmW-8215-A0-06-011
800 mm800 mmW-8215-43-00-011

Roofs and top cover: packing unit 1 pc. For the SZE2 with 1000 or 1200 mm width there is no 400 mm deep roof.

📄 Dimensional drawings in the catalogue: SZE2 p. 29 → · SZE3 p. 74 → · SZE3 p. 94 →
Request with the enclosure →Configure the complete enclosure: in the configurator → · Catalogue number: SZE3 · SZE2

Roof plates and floor plates

The openings in the roof plate of the SZE2 or in the top cover of the SZE3 are closed or opened with roof plates – for air or cables. The full plate retains the degree of protection; every other version reduces it, although a roof fitted above gives more protection than the open enclosure. Roof plates are the same for SZE2 and SZE3.

Roof plates – solid, perforated, filter mat, brush, foam
Roof platesSolid, perforated, filter mat, brush, foam
Sliding floor plates – with foam or brush
Sliding floor platesWith foam or brush
VersionDegree of protection without roofDegree of protection with roofOpening 380 × 380 mmOpening 380 × 210 mm
Solid plateIP 54/55 (SZE2), IP 55 (SZE3)IP 54/55 (SZE2), IP 55 (SZE3)W-4810-07-00-011W-1951-26-00-011
perforatedIP 20IP 21W-1718-39-01-011W-1718-39-02-011
with filter matIP 10IP 21W-1718-42-01-011W-1718-42-02-011
with brush pass-throughIP 00IP 21W-5271-10-00-011W-5271-14-00-011
with foam pass-throughIP 10IP 21W-1718-40-01-011W-1718-40-02-011
with filter mat and brush pass-throughIP 00IP 21W-SB76-00-00-011–

Powder-coated sheet steel RAL 7035, with fixing parts, packing unit 1 pc. The position and dimensions of the openings are shown in the dimensional drawings of the enclosures in the catalogue.

Sliding floor plates

Every enclosure is supplied with simple sliding floor plates for each opening in the floor plate. As replacements there are sets with sealing foam or brush: they form a cable pass-through with adjustable width; the foam protects the cable insulation and increases tightness, the brush keeps dust out. For 800 mm deep enclosures there is a set with two cable pass-throughs (four foam plates and one centre plate). One set applies to one opening – enclosures 1000 and 1200 mm wide have two in the floor plate.

Cabinet widthOpening widthPlate widthSet with foamSet with brushSet with 2 pass-throughs (depth 800 mm)
800 mm586 mm616 mmW-1951-81-01-000W-8186-50-01-000W-5716-13-05-000
600 or 1200 mm386 mm416 mmW-1951-81-02-000W-8186-50-02-000W-5716-13-07-000
1000 mm356 mm386 mmW-1951-81-03-000W-8186-50-03-000W-5716-13-03-000
ComponentKey dataSeriesCatalogue number
Seal for the floor platePU foam, self-adhesive, 3.2 m, under the sliding floor platesSZE2W-1951-45-10-000

Floor plates made of galvanised sheet steel with PU foam or plastic brush, packing unit 1 set; the same for SZE2 and SZE3.

📄 Dimensional drawings in the catalogue: SZE2 p. 50–51 → · SZE3 p. 95–97 →
Request with the enclosure →Configure the complete enclosure: in the configurator → · Catalogue number: SZE3 · SZE2

Baying enclosures

A bayed row needs one connecting set per joint. On the SZE2 it contains screws M8 × 25 with nuts and washers and 6 m of self-adhesive seal; on the SZE3 four frame connectors type A, two type B, 6 m of sealing tape for the joint between the frames and the fixing accessories. Where required, the partition wall goes between the enclosures; across the enclosure boundary the mounting plate connector creates a continuous mounting level.

SZE2 baying accessories – screws M8, washers, 6 m seal
SZE2 baying accessoriesScrews M8, washers, 6 m seal
SZE3 frame connectors – type A and type B, with sealing tape
SZE3 frame connectorsType A and type B, with sealing tape
ComponentContentsSeriesCatalogue number
Baying accessories for 2 enclosures6 screws M8 × 25, 6 nuts M8, 12 washers 8.4, 6 toothed lock washers 8.4, 6 m self-adhesive sealSZE2W-1951-45-00-000
Connecting set for 2 enclosures4 frame connectors type A, 2 type B, 6 m self-adhesive sealing tape, fixing partsSZE3W-6678-00-00-000-EM-S
📄 Dimensional drawings in the catalogue: SZE2 p. 52 → · SZE3 p. 90–91 →
Request with the enclosure →or individually for retrofitting

Plinth: welded or bolted

The welded plinth is intended for heavily loaded enclosures: with it the enclosure can be moved by fork-lift truck without a transport pallet. On the SZE2 it is available 100 or 200 mm high, on the SZE3 100 mm; as a special version ZPAS also builds common welded plinths for several enclosures, for example 200 mm high for two SZE3. The material is powder-coated sheet steel in RAL 7035, and the fixing to the enclosure is included.

Welded plinth – 100 or 200 mm high, suitable for fork-lift trucks
Welded plinth100 or 200 mm high, suitable for fork-lift trucks
Bolted plinth – corners carry the load, panels removable
Bolted plinthCorners carry the load, panels removable
Plinth panels – solid, perforated, with brush pass-through
Plinth panelsSolid, perforated, with brush pass-through
Levelling screw – adjustment range 0–10 mm
Levelling screwAdjustment range 0–10 mm

Welded plinth

Rack depthSZE2 · 100 mm highSZE2 · 200 mm highSZE3 · 100 mm high
Enclosure width 600 mm
400 mmW-1951-71-14-011W-1951-74-14-011W-6282-15-16-011
500 mmW-1951-71-13-011W-1951-74-13-011W-6282-15-15-011
600 mmW-1951-71-12-011W-1951-74-12-011W-6282-15-14-011
800 mmW-1951-71-11-011W-1951-74-11-011W-6282-15-13-011
Enclosure width 800 mm
400 mmW-1951-71-10-011W-1951-74-10-011W-6282-15-12-011
500 mmW-1951-71-09-011W-1951-74-09-011W-6282-15-11-011
600 mmW-1951-71-08-011W-1951-74-08-011W-6282-15-10-011
800 mmW-1951-71-07-011W-1951-74-07-011W-6282-15-09-011
Enclosure width 1000 mm
400 mm––W-6282-15-08-011
500 mmW-1951-71-06-011W-1951-74-06-011W-6282-15-07-011
600 mmW-1951-71-05-011W-1951-74-05-011W-6282-15-06-011
800 mm––W-6282-15-05-011
Enclosure width 1200 mm
400 mm––W-6282-15-04-011
500 mmW-1951-71-03-011W-1951-74-03-011W-6282-15-03-011
600 mmW-1951-71-02-011W-1951-74-02-011W-6282-15-02-011
800 mmW-1951-71-01-011W-1951-74-01-011W-6282-15-01-011

Packing unit 1 pc. For the SZE2 with 1000 mm width the welded plinth is available in 500 and 600 mm depth.

📄 Dimensional drawings in the catalogue: SZE2 p. 31 → · SZE3 p. 77 →

Bolted plinth

The bolted plinth consists of four plinth corners, which carry the entire weight of the enclosure, and removable plinth panels between them. The panels can also be unscrewed with the enclosure loaded – giving access to the space under the enclosure. The plinth is ordered as individual parts: one set of plinth corners plus the panels matching the width and depth. The corners have removable black plastic covers and take either a levelling set (0–10 mm) or vibration dampers made of 10 mm rubber; a plinth with dampers is fixed to the floor. Plinths can be connected side by side (one connecting set) or stacked (two sets per level), at most 4 × 100 mm.

ComponentKey dataSZE2SZE3
Plinth corners (set of 4)100 mm high, sheet steel RAL 7035, plastic covers, with fixingsW-6935-74-00-011W-6935-74-00-011
Levelling set (4 screws)Adjustment range 0–10 mm, galvanised steelW-6935-Z1-02-000W-6935-Z1-01-000
Vibration dampers (set of 4)Rubber 10 mm; fix plinth to the floorW-M1Z-00-0048-000-4W-M1Z-00-0048-000-4
Plinth connection kit4 screws M10 × 20, 4 washers 10.5, 4 flange nuts M10W-6935-Z1-03-000W-6935-Z1-03-000

Plinth panels

Plinth wall lengthPanel lengthSolid panelPerforated panelPanel with brush pass-through
SZE2 – plinth at front or rear
600 mm400 mmW-6935-46-05-011W-6935-92-05-011W-6935-94-05-011
800 mm600 mmW-6935-46-03-011W-6935-92-03-011W-6935-94-03-011
1000 mm800 mmW-6935-46-02-011W-6935-92-02-011W-6935-94-02-011
1200 mm1000 mmW-6935-46-01-011W-6935-92-01-011W-6935-94-01-011
SZE2 – plinth at the side
350 mm150 mmW-6935-46-10-011W-6935-92-10-011W-6935-94-10-011
450 mm250 mmW-6935-46-08-011W-6935-92-08-011W-6935-94-08-011
550 mm350 mmW-6935-46-06-011W-6935-92-06-011W-6935-94-06-011
750 mm550 mmW-6935-46-04-011W-6935-92-04-011W-6935-94-04-011
SZE3 – all sides
400 mm200 mmW-6935-46-09-011W-6935-92-09-011W-6935-94-09-011
500 mm300 mmW-6935-46-07-011W-6935-92-07-011W-6935-94-07-011
600 mm400 mmW-6935-46-05-011W-6935-92-05-011W-6935-94-05-011
800 mm600 mmW-6935-46-03-011W-6935-92-03-011W-6935-94-03-011
1000 mm800 mmW-6935-46-02-011W-6935-92-02-011W-6935-94-02-011
1200 mm1000 mmW-6935-46-01-011W-6935-92-01-011W-6935-94-01-011

Plinth panels made of powder-coated sheet steel RAL 7035, with fixing parts, packing unit 1 pc. For 600 to 1200 mm plinth wall the panels of the SZE2 and SZE3 are identical.

📄 Dimensional drawings in the catalogue: SZE2 p. 32–33 → · SZE3 p. 78–79 →
Request with the enclosure →Configure the complete enclosure: in the configurator → · Catalogue number: SZE3 · SZE2

Castor set and lifting eyes

The castor set for SZE2 and SZE2 PC with 600, 800 or 1000 mm width consists of two swivel castors with brake, two fixed castors and two support rails of enclosure width, fitted at the front and rear of the enclosure. Load capacity 600 kg, overall height 135.5 mm; fixing parts are included.

Lifting eyes are available as single (galvanised forged eye, opening 30 mm, thread M12) and double for enclosure rows (galvanised bracket, opening 38 mm, two holes for M12, with screws). They are sold individually and on the SZE2 are screwed into the roof plate or the spacer sleeves of the roof, on the SZE3 into the upper frame corners.

SZE2 castor set – 600 kg, overall height 135.5 mm
SZE2 castor set600 kg, overall height 135.5 mm
Lifting eyes – double and single, M12
Lifting eyesDouble and single, M12
ComponentKey dataSZE2SZE3
Swivel castors type 300 with brake (2 pcs)for castor setW-SB73-00-01-000-2–
Fixed castors type 300 without brake (2 pcs)for castor setW-SB73-00-02-000-2–
Support rails (2 pcs)RAL 7035, for enclosure width 600 / 800 / 1000 mm600: W-SB74-00-01-011-2
800: W-SB74-00-02-011-2
1000: W-SB74-00-03-011-2
–
Lifting eye, singleOpening 30 mm, thread M12M1F-00-0106M1F-00-0106
Lifting eye, doubleOpening 38 mm, 2 holes M12, with screwsW-1951-68-00-000W-6282-69-00-C12

Load capacities when lifting, according to the catalogue

  • Single enclosure, four eyes, rope angle 60°: max. 550 kg
  • Single enclosure, vertical pull: max. 900 kg
  • SZE2 row of three enclosures with double eyes, 60°: outer enclosures max. 500 kg each, middle one max. 800 kg

For higher loads the catalogue recommends placing the enclosure group on a common welded plinth, which stiffens the structure during transport – the suitable plinth is determined by ZPAS design engineering.

📄 Dimensional drawings in the catalogue: SZE2 p. 30–31 → · SZE3 p. 76 →
Request with the enclosure →or individually for retrofitting

Frequently asked questions — doors, panels, roof and plinths

Which door fits my enclosure?

The catalogue number depends on the series, enclosure height and enclosure width: single door for 600 and 800 mm, double door for 1000 and 1200 mm width. On the SZE2 the accessory door replaces the front door or the rear sheet panel, on the SZE3 it sits at the front, rear or side. Double doors are ordered per leaf.

Flush or protruding side panel on the SZE2?

The flush side panel stays within the frame width and can serve as a partition in an enclosure row; the protruding one widens the enclosure by 25 mm per side. The full roof is available to match both – 50 mm wider for protruding side panels.

Welded or bolted plinth?

The welded plinth is intended for heavy loads and for transport by fork-lift truck without a pallet. With the bolted plinth, four corners carry the weight and the panels can also be removed with the enclosure loaded; the corners take a levelling set (0–10 mm) or vibration dampers, and plinths can be stacked up to 4 × 100 mm.

How heavy may an enclosure be when lifted by its lifting eyes?

According to the catalogue, a single enclosure lifted by four eyes at a 60° rope angle may weigh max. 550 kg, with a vertical pull max. 900 kg. In an SZE2 row of three enclosures with double eyes it is 500 kg each for the outer ones and 800 kg for the middle one. For heavier groups ZPAS recommends a common welded plinth.

How do roof plates change the degree of protection?

With the solid plate the degree of protection of the enclosure is retained. Perforated plates, filter mat, brush or foam pass-through reduce it to IP 00 to IP 20 without a roof, or IP 21 with a roof fitted. The difference between IP 54 and IP 55 is explained in the IP guide.

All questions in the FAQ →

Order accessories or together with the enclosure?

State the series, enclosure size and catalogue numbers – or describe what the enclosure is to do. Quotation within 2 working days at most.