Container data centre
& modular data centre
If there is no server room, the data centre simply comes as a module: in a container, in a walk-in outdoor enclosure or as a compact Databox in a hall. ZPAS supplies the complete interior – racks, containment, cooling, monitoring and access control – as one ready-to-fit system.
Request a quote Configure a DataboxBringing computing power to where it is needed
A container data centre from ZPAS is a modular data centre in a 10/20/40-foot container, in a hall or in a walk-in outdoor enclosure, whose IT interior – Z-SERVER racks, cold aisle containment, cooling and AKCP monitoring – is supplied pre-assembled ex works for 1 to 10+ racks. Not every project gets a classic server room: production sites need edge computing power next to the line, utilities and telcos need IT at outdoor sites, growing companies need fast capacity without conversion work. The answer is modular: a container data centre or a Databox – the enclosed rack cell that stands in a container, in a hall or in a walk-in outdoor enclosure.
For this, ZPAS supplies the complete interior: Z-SERVER racks, cold aisle containment, cooling, AKCP monitoring with access control – pre-assembled, documented, expandable. For small edge sites, there is the Small Data Box as a compact complete solution.
If a single rack is enough for the site, a container is one size too big: this is where the micro data centre comes in – a rack with its own cooling, space for a UPS, access control and monitoring, installed in a hall, branch or technical corridor. As requirements grow, the same modular system leads via containment to the modular solution on this page.
Typical applications
Edge in production
Compact Databox next to the line: 1–4 racks, enclosed and air-conditioned – without a dedicated server room.
Container fit-out
Racks, aisle containment, cable routes and cooling for 10/20/40-foot containers – planned for your shell or supplied with a partner.
IT outdoors
Walk-in outdoor enclosures and outdoor server racks for network nodes and radio sites – −40 to +70 °C.
Server room retrofit
Where a room exists but there is no order: Databox as a room-in-room solution with defined airflow.
Security & access
AKCP access control down to rack level, video and sensors – also for unmanned sites.
Scaling
Bayable racks and modular containment: from 2 to 10 racks without changing systems.
Requirements – clearly classified
Cooling according to load
From split cooling to a cold aisle solution – designed according to heat load, redundant where necessary.
Statics & transport
Z-SERVER racks: 1,600 kg static on levelling feet, 2,000 kg without; bolted down for transport inside the container.
Monitoring ex works
Temperature, humidity, power, door, video – with alarms by e-mail/SMS for unstaffed sites.
Documented & expandable
Drawings, test reports, access to spare parts – and reserve space for the second expansion stage.

Set-up: what is inside the container
A container data centre consists of the shell and the interior. ZPAS supplies the interior as a coordinated system; the shell is provided by you or a container partner. The set-up always follows the same principle:
- Rack row: Z-SERVER racks with 42, 45 or 47 U in 600 or 800 mm width, bayable and bolted down for transport inside the container.
- In-row cooling: in-row heat exchangers stand between the racks and distribute the cold air evenly over the full height. In the catalogue version, the heat exchanger is 300 mm wide with a depth of 1,200 mm and a height of 2,000 mm.
- Airflow: partition elements separate the cold and warm zones at rack level. From a rack row with an aisle upwards, the Databox takes over with sliding doors and roof modules.
- Power: PDUs for each rack, single-phase with 16 or 32 A or three-phase with 3 × 16 or 3 × 32 A.
- Monitoring and access: sensors, door contacts and access control with alarms by e-mail or SMS.
Scope of supply
The scope of supply comprises what is stated in the quotation. These items are typical:
- Z-SERVER racks with 19″ profile rails, cable management and partition elements for airflow
- In-row heat exchangers as direct-expansion units with outdoor unit or for chilled water
- Cold aisle or hot aisle containment as the Databox, when two rows form an aisle
- PDUs from the basic strip to the managed version with metering at the input and outputs
- Monitoring for temperature, humidity and airflow with detection of smoke, power failure, leakage and door opening
- Single doors with 5-point locking and swing handle, on request with electronic handle and remote opening
- Drawings and test reports
What is supplied is the infrastructure, not IT operation. The technical team sizes the cooling on the basis of your equipment list.
Capacity classes
The cooling capacity determines the size of the system. The in-row heat exchangers are available in these stages:
| Technology | Model | Cooling capacity | Fans |
|---|---|---|---|
| Direct expansion (DX) | BWC-DX1 | 4.5 to 8.4 kW | 3 |
| Direct expansion (DX) | BWC-DX2 | 11.2 to 22.3 kW | 5 |
| Chilled water (CW) | BWC-CW1 | 22.6 kW | 3 |
| Chilled water (CW) | BWC-CW2 | 31 kW | 5 |
| Chilled water (CW) | BWC-CW3 | 37.7 kW | 5 |
With direct expansion, an outdoor unit releases the heat to the surroundings; it is available with 4.5 · 8.4 · 11.2 · 14 and 22.3 kW. With the chilled-water system, a chiller supplies the cooled water, on request with free cooling via the outside air. The fans can be replaced individually during operation. On the power side, the PDUs range from 3.6 kW (16 A) through 7.2 kW (32 A) and 11.1 kW (3 × 16 A) to 22.1 kW (3 × 32 A) per PDU.
You can estimate the cooling demand per rack with the cooling capacity calculator. The unit ranges for the individual rack are shown on the server rack cooling page, the choice of cooling level on the server room cooling page.
Process: from enquiry to installation
- 1. Enquiry: location, number of racks and heat load are enough to get started. We will get back to you within 2 working days with a date.
- 2. Sizing: the technical team selects racks, cooling and power distribution on the basis of your equipment list. The containment can be planned in advance in the Databox configurator.
- 3. Planning for the shell: layout plan, cable routes and reserve space are matched to your container or the partner’s shell.
- 4. Production: racks, containment and monitoring are pre-assembled and documented at the factory.
- 5. Delivery and installation: the racks are bolted down for transport inside the container. Which installation services on site are included is stated in the quotation.
Container, Databox or micro data centre?
The three solutions are built on the same Z-SERVER base and differ in size:
- Micro data centre: one to a few racks as a closed unit with its own cooling, space for a UPS, access control and monitoring. It stands in the working area and does not need a server room.
- Databox: the cold aisle or hot aisle containment for rack rows with an aisle width of 1,200 mm, as a room-in-room solution in a hall or server room.
- Container data centre: the same technology in its own shell, when there is no building for it at the site or the capacity has to be in place quickly.
If you start with one rack, you can grow via containment up to the container without changing systems.
Why ZPAS
Because modular data centres fail at the interfaces: racks from one supplier, cooling from another, monitoring from a third. ZPAS supplies the interior as one system with one contact person – planned in the Databox configurator, assembled ex works.
The wider context is described on the industry page Server racks for data centres.
Frequently asked questions
Does ZPAS supply complete container data centres?
ZPAS supplies the complete IT interior – racks, containment, cooling, monitoring, cable routes – to suit your container shell or in cooperation with container partners. The ZPAS technical team handles the planning on a project-specific basis.
What is a Databox?
An enclosed rack cell with defined cold/warm air routing – as a room-in-room solution in a hall or container. Configurable in the Databox configurator, from 1 to 10+ racks.
Can computing power also be located entirely outdoors?
Yes – as a walk-in outdoor enclosure or as an air-conditioned outdoor server rack based on the SZD series with a 19-inch level, operating range −40 to +70 °C.
How are unmanned sites monitored?
With AKCP monitoring ex works: sensors for climate and power, door contacts, cameras and access control – alarms by e-mail/SMS, log for each access.
An edge or container project?
Site, number of racks and heat load are all we need – concept and quotation within 2 working days at most.